जलवायु परीक्षण कक्ष 1000 लीटरCTS
C-55/1000 Li -50°C bis 100°C
जलवायु परीक्षण कक्ष 1000 लीटर
CTS
C-55/1000 Li -50°C bis 100°C
स्थिति
उपयोग किया हुआ
स्थान
Borken 

तस्वीरें दिखाती हैं
मानचित्र दिखाएँ
मशीन के बारे में जानकारी
मूल्य और स्थान
- स्थान:
- Einsteinstraße 8a, 46325 Borken, Deutschland

कॉल करें
प्रस्ताव का विवरण
- विज्ञापन आईडी:
- A17851641
- संदर्भ संख्या:
- 24459
- अद्यतन:
- अंतिम बार 28.11.2024 को
विवरण
CTS
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
Kjdpfeva Hi Hsx Adqefa
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
Kjdpfeva Hi Hsx Adqefa
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
आपूर्तिकर्ता
सूचना: निःशुल्क पंजीकरण करें या लॉगिन करें, सभी जानकारी प्राप्त करने के लिए।
से पंजीकृत: 2012
अनुरोध भेजें
टेलीफ़ोन & फैक्स
+49 2861 ... विज्ञापन
हो सकता है ये विज्ञापन भी आपकी रुचि के हों।
छोटा विज्ञापन
Borken
7,009 km
तापमान परीक्षण कैबिनेट 1000 लीटर
CTST-55/1000 Li -50°C bis 100°C
CTST-55/1000 Li -50°C bis 100°C
छोटा विज्ञापन
Bovenden
6,798 km
अन्य
AtlasMobilbagger AB 1302 D
AtlasMobilbagger AB 1302 D
छोटा विज्ञापन
Borken
7,009 km
वैकल्पिक जलवायु कैबिनेट
BinderMKF 720 E1 / E1.1
BinderMKF 720 E1 / E1.1
छोटा विज्ञापन
Lublin
5,921 km
चिलर/हीट पंप
Used Watercooled Chiller DaikinEWHQ120G 95/130 kW 2019 yom
Used Watercooled Chiller DaikinEWHQ120G 95/130 kW 2019 yom
छोटा विज्ञापन
Burgoberbach
6,740 km
इंजेक्शन मोल्डिंग मशीन
Arburg270U 400-60 199103
Arburg270U 400-60 199103
छोटा विज्ञापन
Borken
7,009 km
आर्द्रता के साथ जलवायु परीक्षण कक्ष
VötschVC³ 4100 990 Liter -42°C bis +180°C
VötschVC³ 4100 990 Liter -42°C bis +180°C
छोटा विज्ञापन
Lublin
5,927 km
चिलर
Used Watercooled Chiller EF COOLINGEVO 90 WKL770FC 88 kW 2019 yom
Used Watercooled Chiller EF COOLINGEVO 90 WKL770FC 88 kW 2019 yom
छोटा विज्ञापन
Odder
6,819 km
टर्मिनल ट्रैक्टर
KalmarTRL618I 4X4
KalmarTRL618I 4X4
छोटा विज्ञापन
Borken
7,009 km
वॉक-इन जलवायु कक्ष
WeissWK 27'/50-150 -50°C bis 150°C
WeissWK 27'/50-150 -50°C bis 150°C
छोटा विज्ञापन
Borken
7,009 km
तापमान परीक्षण कैबिनेट
VötschVTS³ 7018-5
VötschVTS³ 7018-5
आपका विज्ञापन सफलतापूर्वक हटाया गया है
एक त्रुटि हुई है

























































































































