Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
Njdpfx Alsrbiyfs Eewf
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
Njdpfx Alsrbiyfs Eewf
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
अनुरोध भेजें
टेलीफ़ोन & फैक्स
+49 2861 ... विज्ञापन
हो सकता है ये विज्ञापन भी आपकी रुचि के हों।
छोटा विज्ञापन
Ensisheim
6,979 km
3-अक्षीय वर्टिकल मशीनिंग सेंटर
HURCOVM10-24i PLUS CTS
HURCOVM10-24i PLUS CTS
छोटा विज्ञापन
Olching
6,681 km
ऊर्ध्वाधर मशीनिंग केंद्र
FANUCRobodrill D21LIB5
FANUCRobodrill D21LIB5
छोटा विज्ञापन
Gondelsheim
6,880 km
क्रेन आकाश क्रेन इनडोर क्रेन क्रेन रनवे
Demag - Portalkran KBK 125KG KettenzugKBK 1 KBK1 12x3,5m NL 125Kg + Zubehör
Demag - Portalkran KBK 125KG KettenzugKBK 1 KBK1 12x3,5m NL 125Kg + Zubehör
छोटा विज्ञापन
Rochetoirin
7,135 km
ऊर्ध्वाधर मशीनिंग केंद्र
MAZAKVARIAXIS C 600
MAZAKVARIAXIS C 600
छोटा विज्ञापन
Contamine-sur-Arve
7,060 km
सीएनसी स्विस-प्रकार खराद
BOLEYBC20-VI
BOLEYBC20-VI
छोटा विज्ञापन
Lindlar
6,976 km
चमकाने मशीन
PM 1000
PM 1000
छोटा विज्ञापन
Oberweis
6,495 km
सीएनसी मशीनिंग केंद्र
MicrocutChallenger MCV-2418
MicrocutChallenger MCV-2418
छोटा विज्ञापन
Madrid
7,946 km
ट्रक का वजन मापने का पैमाना
Leon
Leon
छोटा विज्ञापन
Cantù
6,845 km
डबल क्रॉस कट आरी
SML - ITALYSILVER P 35/EL
SML - ITALYSILVER P 35/EL
छोटा विज्ञापन
Egenhofen
6,695 km
खींचो आरी
GrauleZS170N
GrauleZS170N
आपका विज्ञापन सफलतापूर्वक हटाया गया है
एक त्रुटि हुई है