Ishida IX-GA-4075-D रंटजन निरीक्षण प्रणाली (2008)Ishida
Röntgeninspektionssystem
Ishida IX-GA-4075-D रंटजन निरीक्षण प्रणाली (2008)
Ishida
Röntgeninspektionssystem
निर्माण वर्ष
2008
स्थिति
उपयोग किया हुआ
स्थान
Menslage 

मूल आधारभूत जानकारी
- मशीन का नाम:
- Ishida IX-GA-4075-D रंटजन निरीक्षण प्रणाली (2008)
- निर्माता:
- Ishida
- मॉडल:
- Röntgeninspektionssystem
- निर्माण वर्ष:
- 2008
- स्थिति:
- उपयोग किया हुआ
मूल्य और स्थान
- विक्रेता का स्थान:
- Mühlenhorst 8, 49637 Menslage, जर्मनी

कॉल करें
प्रस्ताव का विवरण
- विज्ञापन आईडी:
- A21662463
- संदर्भ संख्या:
- DE-INS-ISH-2008-00001
- अद्यतन:
- अंतिम बार 01.07.2026 को
विवरण
Overview
This Ishida IX-GA-4075-D X-ray inspection system was manufactured in 2008 and is designed for high-performance product inspection in food, beverage, and pharmaceutical production environments. The system is primarily used for foreign body detection, identifying contaminants such as metal, glass, stones, and high-density plastics that may not be detected by conventional metal detectors.
In addition to contamination detection, the machine can also support product integrity checks, such as identifying missing components or estimating product consistency. The system is built with a robust stainless steel construction, making it suitable for industrial environments with high hygiene requirements.
The inspection process is based on X-ray imaging, where products pass through the inspection chamber via conveyor. The system analyzes density differences in real time and automatically triggers a reject mechanism if contamination is detected.
Technical Data
Gbedpeyzc D Ujfx Ahgsu
- Construction: Stainless steel frame for hygienic industrial use
- HMI: Integrated touchscreen for operation, calibration, and product changeover
- Electrical Data
- Power supply: AC 230 V, single phase
- Current: 11.0 A
- Frequency: 50 / 60 Hz
- Inspection Function
- Detection of foreign bodies:
- Metal
- Glass
- Stones
- High-density plastics
- Additional capabilities:
- Product integrity verification
- Detection of missing components
- Density-based inspection
This Ishida IX-GA-4075-D X-ray inspection system was manufactured in 2008 and is designed for high-performance product inspection in food, beverage, and pharmaceutical production environments. The system is primarily used for foreign body detection, identifying contaminants such as metal, glass, stones, and high-density plastics that may not be detected by conventional metal detectors.
In addition to contamination detection, the machine can also support product integrity checks, such as identifying missing components or estimating product consistency. The system is built with a robust stainless steel construction, making it suitable for industrial environments with high hygiene requirements.
The inspection process is based on X-ray imaging, where products pass through the inspection chamber via conveyor. The system analyzes density differences in real time and automatically triggers a reject mechanism if contamination is detected.
Technical Data
Gbedpeyzc D Ujfx Ahgsu
- Construction: Stainless steel frame for hygienic industrial use
- HMI: Integrated touchscreen for operation, calibration, and product changeover
- Electrical Data
- Power supply: AC 230 V, single phase
- Current: 11.0 A
- Frequency: 50 / 60 Hz
- Inspection Function
- Detection of foreign bodies:
- Metal
- Glass
- Stones
- High-density plastics
- Additional capabilities:
- Product integrity verification
- Detection of missing components
- Density-based inspection
हो सकता है ये विज्ञापन भी आपकी रुचि के हों।
सफल
आपका संदेश भेज दिया गया है।
छोटा विज्ञापन
आयरलैंड
8,033 km
एक्स रे मशीन
Bizerba X Ray Machine
Bizerba X Ray Machine
सफल
आपका संदेश भेज दिया गया है।
छोटा विज्ञापन
Bydgoszcz
6,265 km
एक्स-रे
IshidaIX-GN-2443-S
IshidaIX-GN-2443-S
सफल
आपका संदेश भेज दिया गया है।
छोटा विज्ञापन
Krotoszyn
6,284 km
प्लैनेटरी मिक्सर
TONELLIUNIVERSAL 2000
TONELLIUNIVERSAL 2000
सफल
आपका संदेश भेज दिया गया है।
छोटा विज्ञापन
Ystad
6,585 km
एक्स-रे स्कैनर
IshidaIX-G2-4027-H
IshidaIX-G2-4027-H
आपका विज्ञापन सफलतापूर्वक हटाया गया है
एक त्रुटि हुई है






















































