थर्मल शॉक टेस्ट चैंबरRS-Simulatoren
ST2K320/45 K
थर्मल शॉक टेस्ट चैंबर
RS-Simulatoren
ST2K320/45 K
स्थिति
उपयोग किया हुआ
स्थान
Borken 

मशीन के बारे में जानकारी
- मशीन का नाम:
- थर्मल शॉक टेस्ट चैंबर
- निर्माता:
- RS-Simulatoren
- मॉडल:
- ST2K320/45 K
- स्थिति:
- बहुत अच्छा (इस्तेमाल किया हुआ)
मूल्य और स्थान
- स्थान:
- Einsteinstraße 8a, 46325 Borken, Deutschland

कॉल करें
प्रस्ताव का विवरण
- विज्ञापन आईडी:
- A22185487
- संदर्भ संख्या:
- 24112
- अद्यतन:
- अंतिम बार 23.06.2026 को
विवरण
RS Simulators
Type: ST2K320/45 K
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
Pgedozgbutjpfx Ac Don
We will be happy to answer any further questions you may have by telephone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
Type: ST2K320/45 K
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
Pgedozgbutjpfx Ac Don
We will be happy to answer any further questions you may have by telephone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
अनुरोध भेजें
टेलीफ़ोन & फैक्स
+49 2861 ... विज्ञापन
हो सकता है ये विज्ञापन भी आपकी रुचि के हों।
छोटा विज्ञापन
Borken
7,009 km
तापीय शॉक परीक्षण संयंत्र
RS-SimulatorenST2K320/45
RS-SimulatorenST2K320/45