विवरण
We are offering a Weiss temperature test chamber for sale.
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Gsdoziyb Ropfx Akbskb
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Gsdoziyb Ropfx Akbskb
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
अनुरोध भेजें
टेलीफ़ोन & फैक्स
+49 2861 ... विज्ञापन
हो सकता है ये विज्ञापन भी आपकी रुचि के हों।
छोटा विज्ञापन
Borken
7,009 km
तापमान परीक्षण कैबिनेट 600 लीटर
WeissWT3-600/40 -42°C bis +180°C
WeissWT3-600/40 -42°C bis +180°C
छोटा विज्ञापन
Aichach
6,698 km
रोल-ऑफ टिपर ट्रक
MERCEDES-BENZ4144 Actros MP2 Abrollkipper 8x8 Singlebereifung
MERCEDES-BENZ4144 Actros MP2 Abrollkipper 8x8 Singlebereifung
छोटा विज्ञापन
Hohenthann
6,627 km
टेलीस्कोपिक लोडर 810 T कूबोटा
Kingway810 T Kubota
Kingway810 T Kubota
छोटा विज्ञापन
Neukamperfehn
6,968 km
पैकिंग टेबल पिकिंग टेबल टेबल
Kommisioniertisch / 2940 x 800 mm /inkl. Regal
Kommisioniertisch / 2940 x 800 mm /inkl. Regal
छोटा विज्ञापन
Chemnitz
6,584 km
विभिन्न रियर वेरिएंट्स के साथ टिपर बॉडी
Container-Vertrieb-ChemnitzGaLa-Bau Container Kippaufbau
Container-Vertrieb-ChemnitzGaLa-Bau Container Kippaufbau
छोटा विज्ञापन
Remscheid
6,986 km
नियंत्रण इकाई
BrinkmannSTC 250 / 720 MVXZ + 459 Tauchpumpe No……- 60664 001 !
BrinkmannSTC 250 / 720 MVXZ + 459 Tauchpumpe No……- 60664 001 !
आपका विज्ञापन सफलतापूर्वक हटाया गया है
एक त्रुटि हुई है