संयुक्त ताप और बिजली संयंत्रagriKomp GmbH
BGA/NGA168
संयुक्त ताप और बिजली संयंत्र
agriKomp GmbH
BGA/NGA168
निर्माण वर्ष
2024
स्थिति
नई
स्थान
Merkendorf 

तस्वीरें दिखाती हैं
मानचित्र दिखाएँ
मशीन के बारे में जानकारी
- मशीन का नाम:
- संयुक्त ताप और बिजली संयंत्र
- निर्माता:
- agriKomp GmbH
- मॉडल:
- BGA/NGA168
- निर्माण वर्ष:
- 2024
- स्थिति:
- नया
- कार्यक्षमता:
- पूरी तरह से कार्यरत
मूल्य और स्थान
- स्थान:
- Energiepark 2, 91732 Merkendorf, Deutschland

कॉल करें
तकनीकी विवरण
- शक्ति:
- 350 किलोवाट (475.87 एचपी)
प्रस्ताव का विवरण
- विज्ञापन आईडी:
- A16761621
- अद्यतन:
- अंतिम बार 09.09.2024 को
विवरण
Compact, highly efficient combined heat and power unit with a state-of-the-art SCANIA V 8-cylinder, lean-burn gas turbo, 4-stroke gas Otto engine. Unit, gas pressure control system, mixture and engine water cooling circuit mounted on base frame for power and heat generation with a high-quality synchronous generator (3P, 400V, 50Hz) for mains/parallel operation and optimized heat extraction via plate heat exchanger for heating water/process heat with a temperature level of VL 85°C / RL 70°C,
OPTIONAL: with catalytic converter (optional SCR system) for low-emission operation in accordance with the MCP Directive (EU) and 44th BImSchV (DE).
TECHNICAL DATA
GENSET /CHP - Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output motor at 180^exhaust gas temperature: 334 kWth
Electricity coefficient el/th. : 1,05
Engine type V8
Displacement: 16 Ltr
Combustion thermal output - 100% load: 845kWel
Gas consumption at50%CH4: 169.1Nm³/h
Length x width x height m 4.1 x 1.5 x 2.1
Weight unfilled 4500kg
The CHP has a control cabinet with a display for the visualization of all relevant operating parameters including a DSL modem for remote maintenance and external monitoring, as well as an interface for control energy for connection to the Energiepilot E2M. The scope of delivery includes a mains starter to provide the optimum starting speed, as well as a gas detector, smoke detector, emergency stop switch and alarm flashing light/horn.
All pipes are made of V2A and insulated where necessary.
To ensure that the motors are kept warm, the installed heat pumps are programmed to start up in a set cycle,
that they start up in a set cycle and thus enable the desired temperature to be maintained.
An automatic gas shut-off valve for installation outside the CHP installation room is not included in the scope of delivery.
The CHP unit complies with the medium-voltage directive VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP installation room and all operating fluids are not included in the scope of delivery.
Isdpst Uu Ezjfx Adqstr
The CHP unit is also optionally available in a container.
The entire unit is also available as a natural gas version.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
OPTIONAL: with catalytic converter (optional SCR system) for low-emission operation in accordance with the MCP Directive (EU) and 44th BImSchV (DE).
TECHNICAL DATA
GENSET /CHP - Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output motor at 180^exhaust gas temperature: 334 kWth
Electricity coefficient el/th. : 1,05
Engine type V8
Displacement: 16 Ltr
Combustion thermal output - 100% load: 845kWel
Gas consumption at50%CH4: 169.1Nm³/h
Length x width x height m 4.1 x 1.5 x 2.1
Weight unfilled 4500kg
The CHP has a control cabinet with a display for the visualization of all relevant operating parameters including a DSL modem for remote maintenance and external monitoring, as well as an interface for control energy for connection to the Energiepilot E2M. The scope of delivery includes a mains starter to provide the optimum starting speed, as well as a gas detector, smoke detector, emergency stop switch and alarm flashing light/horn.
All pipes are made of V2A and insulated where necessary.
To ensure that the motors are kept warm, the installed heat pumps are programmed to start up in a set cycle,
that they start up in a set cycle and thus enable the desired temperature to be maintained.
An automatic gas shut-off valve for installation outside the CHP installation room is not included in the scope of delivery.
The CHP unit complies with the medium-voltage directive VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP installation room and all operating fluids are not included in the scope of delivery.
Isdpst Uu Ezjfx Adqstr
The CHP unit is also optionally available in a container.
The entire unit is also available as a natural gas version.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
आपूर्तिकर्ता
सूचना: निःशुल्क पंजीकरण करें या लॉगिन करें, सभी जानकारी प्राप्त करने के लिए।
अनुरोध भेजें
टेलीफ़ोन & फैक्स
+49 9826 ... विज्ञापन
हो सकता है ये विज्ञापन भी आपकी रुचि के हों।
छोटा विज्ञापन
Sonsbeck
7,046 km
संयुक्त ताप एवं विद्युत संयंत्र
G2MWM
G2MWM
छोटा विज्ञापन
आयरलैंड
8,033 km
कोलिमैटिक थर्मोफॉर्मर 2021 € 29,990
Colimatic ThermoformerThera 450 L
Colimatic ThermoformerThera 450 L
छोटा विज्ञापन
Naprawa
6,077 km
लामेला बैंड देखा
TOPCUT500
TOPCUT500
छोटा विज्ञापन
Hessisch Lichtenau
6,811 km
पाइप बेंडिंग मशीन, डॉर्न बेंडिंग मशीन, पाइप और प्रोफ़ाइल के लिए बेंडिंग मशीन; सर्वो मोटर के साथ, पाइ
SIEMENS1FK6061-7AF71-1EG0
SIEMENS1FK6061-7AF71-1EG0
छोटा विज्ञापन
Osnabrück
6,933 km
कन्वेयर बेल्ट बंकर कन्वेयर
KlankeFBA1100
KlankeFBA1100
छोटा विज्ञापन
Vreden
7,016 km
ट्रांसफार्मर
N/A800kVA
N/A800kVA
छोटा विज्ञापन
Wiefelstede
6,930 km
3.8 kVA विद्युत जनरेटर
MakitaG4300IS
MakitaG4300IS
छोटा विज्ञापन
Bruckmühl
6,636 km
संयुक्त ताप एवं विद्युत संयंत्र
JenbacherJGC 312 GS-N.LC
JenbacherJGC 312 GS-N.LC
छोटा विज्ञापन
स्लोवेनिया
6,388 km
भाप बॉयलर
LOOS
LOOS
छोटा विज्ञापन
Olching
6,681 km
सीएनसी लेथ
ROMIC570
ROMIC570
आपका विज्ञापन सफलतापूर्वक हटाया गया है
एक त्रुटि हुई है








































































