Pacific Scientific 3313LL Met One पार्टिकल काउंटरPacific Scientific
3313LL Met One
Pacific Scientific 3313LL Met One पार्टिकल काउंटर
Pacific Scientific
3313LL Met One
स्थिति
उपयोग किया हुआ
स्थान
Duxford 

तस्वीरें दिखाती हैं
मानचित्र दिखाएँ
मशीन के बारे में जानकारी
मूल्य और स्थान
- स्थान:
- Duxford, UK

कॉल करें
प्रस्ताव का विवरण
- विज्ञापन आईडी:
- A20502585
- संदर्भ संख्या:
- 23241.SR11B
- अद्यतन:
- अंतिम बार 11.11.2025 को
विवरण
This listing is for a Pacific Scientific 3313LL Met One Particle Counter
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Fpedpfexv Ab Hjx Abpop
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
The unit is in full working condition and is ready for immediate release.
Operational & Practical Notes / Behavior
The 3313LL counts particles by passing a laser (or light source) through the sampled air stream; when particles pass through the beam, they scatter light, which is detected by a photodetector.
By having multiple size channels, the instrument can bin the counts into different particle-size ranges (for example: 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm).
It likely offers programmable sampling intervals, hold times, alarm thresholds, etc. (common features in Met One/Met One‑type instruments).
Data export via serial is standard, allowing integration with control or data acquisition systems.
Fpedpfexv Ab Hjx Abpop
Because it’s a relatively high‑flow device (1 CFM), it can sample a substantial volume of air (improving statistical confidence in counts).
The stainless steel construction helps with durability, cleanliness, and possibly resistance to corrosion or harsh environments.
As a used / legacy device, calibration, maintenance, and replacement parts (filters, laser, pump, optics) may be important considerations.
आपूर्तिकर्ता
सूचना: निःशुल्क पंजीकरण करें या लॉगिन करें, सभी जानकारी प्राप्त करने के लिए।
अनुरोध भेजें
टेलीफ़ोन & फैक्स
+44 20 38... विज्ञापन
आपका विज्ञापन सफलतापूर्वक हटाया गया है
एक त्रुटि हुई है


















