डिफरेंशियल स्कैनिंग कैलोरीमीटरPerkin Elmer
DSC 8000, N5340524
डिफरेंशियल स्कैनिंग कैलोरीमीटर
Perkin Elmer
DSC 8000, N5340524
EXW स्थिर मूल्य कर के अतिरिक्त
€29,750
स्थिति
उपयोग किया हुआ
स्थान
Dresden 

तस्वीरें दिखाती हैं
मानचित्र दिखाएँ
मशीन के बारे में जानकारी
- मशीन का नाम:
- डिफरेंशियल स्कैनिंग कैलोरीमीटर
- निर्माता:
- Perkin Elmer
- मॉडल:
- DSC 8000, N5340524
- स्थिति:
- उपयोग किया हुआ
मूल्य और स्थान
EXW स्थिर मूल्य कर के अतिरिक्त
€29,750
- स्थान:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

कॉल करें
प्रस्ताव का विवरण
- विज्ञापन आईडी:
- A21283042
- संदर्भ संख्या:
- LW43630
- अद्यतन:
- अंतिम बार 20.02.2026 को
विवरण
Perkin Elmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Dodjyluicjpfx Aatocf
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
Model: DSC8000
Type: N5340524
Dodjyluicjpfx Aatocf
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
आपूर्तिकर्ता
सूचना: निःशुल्क पंजीकरण करें या लॉगिन करें, सभी जानकारी प्राप्त करने के लिए।
से पंजीकृत: 2014
97 ऑनलाइन विज्ञापन
अनुरोध भेजें
टेलीफ़ोन & फैक्स
+49 351 8... विज्ञापन
हो सकता है ये विज्ञापन भी आपकी रुचि के हों।
छोटा विज्ञापन
Hannover
6,817 km
डेस्कटॉप मेटल स्टूडियो सिस्टम II
Desktop MetalStudio System II
Desktop MetalStudio System II
छोटा विज्ञापन
Borken
7,009 km
10°C से +250°C / 749 लीटर
Memmert Universal - WärmeschrankUFP 800
Memmert Universal - WärmeschrankUFP 800
छोटा विज्ञापन
Wald
6,842 km
यूनिवर्सल ओवन / हीट कैबिनेट
MemmertULP 600
MemmertULP 600
छोटा विज्ञापन
स्पेन
6,946 km
DESKTOP METAL मेटल स्टूडियो 2
DESKTOP METALMetal Studio 2
DESKTOP METALMetal Studio 2
आपका विज्ञापन सफलतापूर्वक हटाया गया है
एक त्रुटि हुई है




















































