विवरण
White
Type: WK1-1000/70
Weiss climatic test chamber water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered by simply touching the function icons on the
all control and operating commands by simply touching the function icons.
Feedthroughs
The test chamber is equipped with feed-throughs on the right and left side.
Measurement cables and test equipment can be routed into the test chamber through these.
Feed-throughs:
1 feed-through ∅ 125 mm installed on the right
1 feed-through ∅ 50 mm installed on the left
Volume 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, 1980 mm
Data for temperature tests:
Minimum temperature -70 °C
Maximum temperature +180 °C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 2 K
Temperature change rate, heating 4 K/min
Temperature change rate, cooling 2.5 K/min
Max. heat compensation 2750 W
Data for climate tests:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ± 1 K
Humidity deviation, temporal ± 1 to ± 3% r.h.
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A Nominal power 19.8 kW
Refrigerant: R-452A/ R23
Weight approx. 910kg
The following information is for your safety as a buyer!
Nkodpfx Aasrvx Ezszsu
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
Type: WK1-1000/70
Weiss climatic test chamber water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered by simply touching the function icons on the
all control and operating commands by simply touching the function icons.
Feedthroughs
The test chamber is equipped with feed-throughs on the right and left side.
Measurement cables and test equipment can be routed into the test chamber through these.
Feed-throughs:
1 feed-through ∅ 125 mm installed on the right
1 feed-through ∅ 50 mm installed on the left
Volume 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, 1980 mm
Data for temperature tests:
Minimum temperature -70 °C
Maximum temperature +180 °C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 2 K
Temperature change rate, heating 4 K/min
Temperature change rate, cooling 2.5 K/min
Max. heat compensation 2750 W
Data for climate tests:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ± 1 K
Humidity deviation, temporal ± 1 to ± 3% r.h.
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A Nominal power 19.8 kW
Refrigerant: R-452A/ R23
Weight approx. 910kg
The following information is for your safety as a buyer!
Nkodpfx Aasrvx Ezszsu
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
इस विज्ञापन का स्वचालित रूप से अनुवाद किया गया है। अनुवाद में त्रुटियाँ संभव हैं।
आपूर्तिकर्ता
सूचना: निःशुल्क पंजीकरण करें या लॉगिन करें, सभी जानकारी प्राप्त करने के लिए।
से पंजीकृत: 2012
अनुरोध भेजें
टेलीफ़ोन & फैक्स
+49 2861 ... विज्ञापन
हो सकता है ये विज्ञापन भी आपकी रुचि के हों।
छोटा विज्ञापन
Birmingham
7,603 km
रिवेटिंग मशीन
Haeger412
Haeger412
छोटा विज्ञापन
Berlin
6,575 km
कॉम्बी लैमिनेटिंग मशीन
NordmeccanicaSuper Combi 3000
NordmeccanicaSuper Combi 3000
छोटा विज्ञापन
Borken
7,009 km
आर्द्रता 34 लीटर के साथ जलवायु कैबिनेट
WeissWKL 34/60 -60°C bis 150°C
WeissWKL 34/60 -60°C bis 150°C
छोटा विज्ञापन
Zuchwil
6,964 km
उष्मा उपचार भट्टी को प्रत्युत्तर दें
MUT360/400-1150
MUT360/400-1150
छोटा विज्ञापन
Terrassa
7,451 km
रोटरी फलक वैक्यूम पंप
Oerlikon LeyboldSV 300
Oerlikon LeyboldSV 300
छोटा विज्ञापन
Işıktepe OSB
5,193 km
प्रेस ब्रेक
BaykalBAYKAL CNC APHS HYBRID PRESS BRAKE
BaykalBAYKAL CNC APHS HYBRID PRESS BRAKE
छोटा विज्ञापन
जर्मनी
6,760 km
खंड तह बेंच 1.25 मीटर, झुकने वाली मशीन
Prod-Masz Segmentabkantbank Abkantbank24Abkantbank 1,25m/1.5 3 fach segmentiert
Prod-Masz Segmentabkantbank Abkantbank24Abkantbank 1,25m/1.5 3 fach segmentiert
छोटा विज्ञापन
Birmingham
7,603 km
प्रेस ब्रेक
ErmakMicrobend 1000x40
ErmakMicrobend 1000x40
छोटा विज्ञापन
Kaunas
5,938 km
उच्च दबाव वाशिंग मशीन / पंप
WATECH ASMS36
WATECH ASMS36
छोटा विज्ञापन
Nettetal
7,055 km
शीतलन मशीन, ठंडा पानी सेट, कूलर,
MTA S.p.A., KühlmaschinenGalaxy GLT 135 SHE – 354 kW
MTA S.p.A., KühlmaschinenGalaxy GLT 135 SHE – 354 kW
आपका विज्ञापन सफलतापूर्वक हटाया गया है
एक त्रुटि हुई है